Print Email Facebook Twitter High-speed Data Acquisition and Processing for Transcranial Functional Ultrasound Brain Imaging Title High-speed Data Acquisition and Processing for Transcranial Functional Ultrasound Brain Imaging Author de Jong, Jan (TU Delft Electrical Engineering, Mathematics and Computer Science; Erasmus Medical Center) Contributor Wong, J.S.S.M. (mentor) Strydis, C. (mentor) Pertijs, M.A.P. (graduation committee) Kruizinga, P. (graduation committee) Degree granting institution Delft University of Technology Programme Computer Science Date 2022-06-29 Abstract Functional ultrasound is by now a well-established technique in the neuroscience community to measure brain activity. However, the transcranial application of functional ultrasound on humans, with the exception of the acoustic windows in the skull, remains a huge challenge because of the properties of the cranial bone the acoustic waves will reflect, refract, attenuate or will cause aberration. Therefore, the signal-to-noise ratio (SNR) of the incoming signal is too low for transcranial functional ultrasound (TCfUS). This thesis tries to overcome the SNR problem of TCfUS with the design of a 64-channel ultrasound acquisition system that is focused on achieving the highest SNR possible. This is achieved by placing the analog front-end (AFE) chips as near to the transducer elements as possible and by oversampling the incoming signal with a factor of 25, a theoretical increase of 15 dB of the signal-to-quantization-noise ratio over the current state-of-the-art is estimated. The proposed design is a receive-only system where the transmission of the ultrasound pulses is carried out by a separate ultrasound system. The design splits the acquisition system into a front-end and a back-end subsystem, where the front-end system is implemented using four AFE58JD48 analog front-end chips from Texas Instruments. From here the data samples are transported over fiber optics to the back-end subsystem, which consists of a VCK190 FPGA board from Xilinx, where the samples are processed and/or transported to a workstation for storage. Because the system organization differentiates from more conventional research ultrasound systems, a trade-off is introduced between processing and throughput, resulting in three processing configurations for the FPGA with each a different focus: raw RF data sampling, real-time processing, and hardware processing. Due to time and resource constraints, no measurements and results are available on the SNR and decimation. However, a theoretical exploration has been done on the expandability of the number of channels which was found to be 192 channels for the VCK190. Subject Functional UltrasoundTranscranialFPGAAcquisition systemUltrasound ImagingSystem Architecturehigh-speedbrain imaging To reference this document use: http://resolver.tudelft.nl/uuid:42ef4901-10ca-4730-9cf8-b40a34b37a17 Bibliographical note https://ultrasoundbrainimaging.com/ Website CUBE https://neuro.nl/ Website department of Neuroscience at Erasmus MC https://neurocomputinglab.com/ Website Neuro Computing Lab Part of collection Student theses Document type master thesis Rights © 2022 Jan de Jong Files PDF Thesis_JandeJong_repo.pdf 14 MB Close viewer /islandora/object/uuid:42ef4901-10ca-4730-9cf8-b40a34b37a17/datastream/OBJ/view